Intelligent power sequencer (P-802A/P-802) functional features:
1. Working environment: 180VAC ^ 240VAC;
2. Power input: 3x2 square power cord with plug (can be equipped with 3x6 square power cord without plug), live wire L, neutral wire N, and ground wire GND;
3. The maximum output load of the entire equipment is 40A;
4. The maximum output load of a single channel is 15A;
5. The total power is 6000W, and the maximum capacity of a single circuit is 2000W;
6. The 6.2-inch LED intelligent display screen can display the current voltage in real time (P-802 does not have a display screen configured);
7. 8 channel inputs, with a delay time of 0.88 seconds for each channel, and each channel can be individually controlled;
8. 2 front panel universal socket direct output;
9. Cascade automatic detection: The current state of the fully automatic detection equipment is four states: host state, slave state, independent use, and central control state;
10. Support cascading sequential control of unlimited sequencer devices by simply operating the host to achieve sequential control of the slave;
11. Cascading can achieve plug and play by simply turning off the host sequencer, which is convenient and fast;
12. Socket standard: compatible with national standard 6A, 10A, 16A, British standard 13A, American standard 15A, and European standard G/M plugs;
13. Body height: 1U